Aqualine Reverse Osmosis is a membrane process that can separate undesirable minerals from water where classical purification methods are insufficient. It can be used on sea water, well water with high conductivity and can produce water of high purity.
AQUALINE ALFA COMPACT SERIES REVERSE OSMOSIS SYSTEMS
0,75 m3/day to 2,4 m3/day
STANDART FEATURES
- Membrane vessels FRP or SS
- TFC Spiral wound membranes 2,5” and 4\” diameter
- Brass body rotary vane type pressure pump
- Epoxy painted cabinet
- 25 micron and 5 micron Cartridge filters
- 2pcs Coconut CTO Block carbon filtres
- Low and High pressure Flexible pipings Polyurethane PN10
- Inlet selonoid valve
- Low and High levels switches
- Product and Drain water line flowmeters
- Gliserin filled manometers
- Product water conductivity meter (0-2000µS/cm)
- Autoflush system
- On-Off switch
- Electronic control card with Alarm and Position indicators
- 220 V/50Hz/1ph
- IP56 Electronic control panel
- ASC dosing pump and tank
- E-50 Ultraviolet Systems (optional)
Recommended Feed water Limits
Feed water TDS : 0 to 2,000 ppm
Operating pressure 10 to 15 bar
Feed water pressure 2 to 5 bar
Over 3 French hardness degree need to dose Antiscalant
Feed water pH range 6 – 8
Silica (SiO2) Tolerance 25 ppm max. @ 60% recovary
Max. Feed water temperature 30º C Max.
Max Iron (Fe) tolerance 0.05 ppm , If available Antiscalant dosing 0,2 ppm
Hydrogen Sulfide should be removed
Turbidity should be removed ( NTU